ISO/IEC 22237 Design Certification (DCDV)


ISO/IEC 22237 Design Certification (DCDV) indicates that the design documents of the data center under scope have been reviewed for conformity to the design criteria of the EN-50600 standard for the respective Class level.

The ISO/IEC 22237 Design Certification is valid for one year, extendable if a site is not operational yet.

EPI is well positioned to conduct ISO/IEC 22237 data center audits as we are, already for more than 30 years, an organization specialized in data center services. EPI is incorporated as an RCB (Registered Certification Body) and has accreditation from a variety of accreditation bodies such SAC, APMG and CERTAC.

Request for a quote

 


About ISO/IEC 22237

The ISO/IEC 22237 is a European standard that provides specifications for the planning, construction and operation of a data center. As part of the DCCC audit, the data center will be reviewed for conformity to the following categories as defined in the ISO/IEC 22237 Standard:

  • ISO/IEC 22237-2: Building construction
  • ISO/IEC 22237-3: Power distribution
  • ISO/IEC 22237-4: Environmental control
  • ISO/IEC 22237-5: Telecommunications cabling infrastructure
  • ISO/IEC 22237-6: Security systems

For the criteria described in ISO/IEC 22237-2 till ISO/IEC 22237-5 the data center will receive an Availability Class Rating, as well as an overall rating level for the whole data center (1-4). For the criteria mentioned in the ISO/IEC 22237-6, the data centre will receive a Protection Class rating (1-4).

 

Availability Class Ratings**

ISO/IEC 22237 describes four availability classes for which data centers can be classified. Below are the high-level descriptions of each rating level.  

  • Availability Class-1: Basic Site Infrastructure
    A data center which has single capacity components and a single, non-redundant distribution path serving the ICT equipment.  
     
  • Availability Class-2: Redundant Capacity Component Site Infrastructure
    A data center which has redundant capacity components and a single, non-redundant distribution path serving the ICT equipment.   
     
  • Availability Class-3: Concurrently Maintainable Site Infrastructure
    A data center which has multiple independent distribution paths serving the ICT equipment. From a conformity point of view, it is acceptable to have one distribution path serve the ICT equipment with the second distribution path to be on standby for maintenance purposes. However, most data centers use both distribution paths on a continuous basis. The data center is required to be concurrently maintainable meaning that each and every capacity component including elements/components which are part of the distribution path, can be removed/replaced/serviced on a planned basis without disrupting the ICT capabilities to the End-User.
     
  • Availability Class-4: Fault Tolerant Site Infrastructure
    A data center which has multiple independent distribution paths serving the ICT equipment which are all active. The data center allows concurrent maintainability and one (1) fault anywhere in the installation without causing downtime. The data center must be capable to automatically detect a fault, automatically isolate the fault and to automatically continue operation.

Note**; For a full description, please refer to the ISO/IEC 22237 Standard.

 

Protection Class Ratings**

ISO/IEC 22237 describes four protection classes for which various areas of the data centre can be classified. For example, the staging area could have a different protection class rating compared to the computer room. Below are the high-level descriptions of each rating level against which the computer room area(s) will be assessed. 

  • Protection Class-1:
    An area which is public or semi-public. The area has no special protection against internal fire. There is no special protection applied against environmental events.
     
  • Protection Class-2:
    An area which is accessible to authorized individuals only. The area has fire detection and suppression. Mitigation is applied against environmental events.
     
  • Protection Class-3:
    An area which is restricted to specified individuals only. Other individuals are required to be accompanied by a specified individual. The area has fire detection and suppression. Mitigation is applied against environmental events.
      
  • Protection Class-4:
    An area which is restricted to specified employees only. Other individuals are required to be accompanied by a specified employee. The area has fire detection and suppression.

Note**; For a full description, please refer to the ISO/IEC 22237 Standard.


 
Training
• Foundation
Risk

Find a Training Schedule

EPI Data Center Framework

EPI Data Centre Operations Standard (DCOS)

EPI Data Centre Conpetence Framework

EPI Data Center Training Framework

IT Training Framework

Make an enquiry
Send me updates
Copyright EPI Singapore 2024      | Privacy Policy | Terms & Conditions

Message Us